We offer and pride in our product and services for Energy and Power. We have been known as innovators and pioneers in design, consultancy and supply of advanced Photovoltaic and DC/AC Power to answer the requirements of various industries.
We master all the stages of solutions, products and services delivering on global level for a number of applications.
Our solutions include specialist stages of designs, engineering works, supply, trainings, integrations, installations and consultancy domains.
Our three principal business sectors are:
Our products and services are offered globally with the help of strong professional partners and agents. We offer a complete integrated service, from design, through to the solar modules, special industrial rated batteries, power control electronics, load equipment, aircraft tugs and ground power units.
TDHV increasingly offers full turn-key project services including installation, commissioning and comprehensive in house as well as on-site professional trainings. Our skilled engineering team, together with substantial R&D supported internationally, provide full service to our customers on small as well as large mega power projects. System sizing using latest CAD facility, installation, testing, training, commissioning and after sales service are pride of our business.
We partner with principle manufacturers and committed to serve commercial aviation, military, industrial and transit customers with robust, reliable and highly functional Tow Tractors and Ground Power Units. It is our goal to provide the highest quality equipment and the highest level of customer service to its customers.
Other than GSE, we supply and comply with your custom designed requirement of Aviation Obstruction and Heliport Lights, and Windsocks.
Sustainable development underpins our work and visions. These visions are the cross cutting of economy (economic growth), society (people and institutional development and empowerment) and environment (environmental protection and enhancement). With these in mind, we mark our presence in the design till installation of renewable power generation products and services with as much social, environmental and economic benefits as possible.
Our aim is to become a trusted source for and a global leader in renewable energy solutions to address the climate change challenge guided by UK, European and international principles, standards and policies.
In Europe, the European Commission officials have set individual country targets for renewable-energy use to reach 20% sourced from wind, solar and biofuels by 2020. TDHV is a strong believer in the strengths of building alliances and working in partnership with the private, public, government and the non-for-profit sectors to find common vision.
It is one planet, and solidarity to control and mitigate climate change should be a priority for all.
Registered in England & Wales: 06461285
Registered address:
TDH Visions,The Nova Building,Herschel Street,Slough - SL1 1XS,Berkshire,United Kingdom.
| TDH VISIONS, UK |
| The Nova Building |
| Herschel Street |
| Slough, SL1 1XS |
| Berkshire |
| United Kingdom |
| tel1: +44 (0) 1753 701056 |
| tel2: +44 (0) 1753 369839 |
| fax: +44 (0) 1753 701107 |
| email: info@tdhvisions.com |
| web: www.tdhvisions.com |
| Technical Queries |
| technical@tdhvisions.com |
| Sales Enquiries |
| sales@tdhvisions.com |
| Accounts Department |
| accounts@tdhvisions.com |
| Training Schedules |
| trainings@tdhvisions.com |
| Procurement Department |
| procurement@tdhvisions.com |
| General Information |
| info@tdhvisions.com |
According to the Energy Saving Trust, the average 3 bedroom house consumes 3,300 units of electricity (kWh) a year (cooking and heating using non electric supply). However, we always recommend that you look at your last few bills or call your electricity supplier to find out how many units you consume, you can then compare this to the output of the system we recommend.
Photovoltaic cells do not need to be in direct sunlight to work, and will generate electricity even on cloudy days. The brighter the day the greater the energy generated. Solar thermal systems will supply hot water on bright days in summer and winter, typically delivering over 60% of hot water demand over the course of a year.
A solar installation adds as little as 4% to the build cost of an average three bedroom home, but over 10%to its final value when sold. It also helps ?future proof? a home against rising fuel prices making properties doubly attractive to price conscious house buyers; as fuel prices continue to rise, energy efficient renewably powered homes will continue to sell at a premium.
Solar photovoltaic systems are silent in operation, have no moving parts and require no maintenance. Solar thermal systems have a few moving parts (inside the pump) but these are virtually maintenance free, you may need to replace the anti-freeze in a solar thermal system after about five years. Most of the time the rain will keep the modules clean. However, a build up of dirt can affect system performance. The modules can be cleaned with either a hose or, if possible, soapy water and a non abrasive brush.
Yes, we sell both types of solar systems: Solar photovoltaic (PV) systems which generates electricity from daylight and solar thermal systems to heat water.
No local battery storage is required as the systems connect to the local electricity supply; in case of BIPV systems installations.
Our photovoltaic systems for homes are entirely grid connected. If there is a power cut your system is automatically switched off. This is a safety measure designed to stop electricity leaking on to the national grid and to protect individuals who may be working to restore the power supply.
Shading is critical. Minor shading can result in significant loss of energy. This is because the cell with the lowest illumination determines the operating current of the series string in which it is connected. Many modern modules use bypass diodes to minimise shade effects; but these effects must still be considered, preferably in the first stages of building design. Watch for landscaping, trees and even handrails. If shading is unavoidable, or poor light is expected on a regular basis, the best types of PV to use are amorphous thin-film, or hybrid (mixing monocrystalline and amorphous technology).
A project with a brief incorporating social and technical innovation is an ideal candidate for building-integrated PV (BIPV). The most important aspect to consider is the location of the site. The solar installation must receive as much light as possible. Shadows cast by tall trees and neighbouring buildings must be kept in mind during the design process. The best location for solar PV is obviously on the south-facing roof or side of a building.
The following energy outputs can be used as a rough rule of thumb for the UK (assuming a reasonable tilt, orientation and system efficiency).
1m2 crystalline array will provide a useful output of 90-110 kWh per year.
1m2 triple-junction thin film array will provide a useful output of 50-60 kWh per year.
The maximum total annual solar radiation is usually at an orientation due south and at a tilt from the horizontal equal to the latitude of the site minus approximately 20 degrees. For example 30 degrees is an optimal tilt in Southern England, increasing to almost 40 degrees in Northern Scotland.
If the optimum angle is not achievable, over 90% of the maximum annual energy can still be achieved at 10 degree and 50 degree tilts.South-facing vertical fs generate around 70% of the maximum.
The main points to remember are:
Orientation, shading and the temperature of the PV elements all impact on their output and must be considered at the design stage. Of course, the more energy efficient the building, the greater the overall benefit of the PV cells. Some PV products have now been designed to provide thermal insulation as well as electricity - eg flat roof systems and solar metal roofing systems that include insulation lass.
British Standards
BS EN 61215
BS EN 61646
The Electric Supply Regulations 1988
The Building Regulations 1991 (and amendments)
The Construction (Design and Management) Regulations 1994
The main issues to be aware of when appraising PV for CDM are:
Weight: Modules may be heavy with some exceeding 50kg.
Toxicity: No PV module releases sufficient toxic materials to cause any harm during installation or maintenance. A small proportion of PV contains cadmium, the oxides of which are toxic in very small doses. Some of these may release toxic dust if crushed during disposal. None of the PV products supplied by TDH Visions contain any cadmium.
PV glass laminates are attractive and well suited to facades and transparent roof tops. They can be fitted to standard curtain walling structures and are suitable for any application where glass is used, as long as there is a reasonable level of light present. Low emissivity glass can be used to give additional thermal insulation benefits, or a PVB laminate can be used for the extra strength required by a roof top. Thin-film PV is durable and flexible and is encased in a water-proof, self-cleaning polymer. It can be used in shingle form for roofing or in more unusual designs that exploit its flexibility.
The degree of soiling will depend on the location but usually dust accumulation and self-cleaning reach a steady state after a few weeks if the array tilt is at least 15 degrees. In extreme cases dust may cause a power reduction of about 10%. At low tilts horizontal glazing bars can trap debris which could lead to shading of part of the array. The design of the system should aim to minimise uneven soiling.
Solar modules have a manufacturers warranty of 25 years and a working lifetime of 40 years and beyond. Modules of all types usually have a twenty year warranty, as do most thin-film integrated products. Crystalline PV slates and PV glass laminates usually have a ten year warranty. These times are only a rough guide and should be checked for each specific product. l a solar system.
Solar PV modules constructed with a glass front have two characteristics that reduce light reflection. In order to optimise electrical yield the glass is treated with an anti-reflective coating which greatly increases the transmittance through the glass so to maximise the amount of light reaching the solar cells. Secondly the outer face of the glass has a slight granular textured. The result is a matt like finish rather than a mirrored, again this is actually intended to maximise yield. These two characteristics greatly reduce reflection from the glazed front face of solar PV modules when compared with conventional glazing.